Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 7.635
1.
EuroIntervention ; 20(9): 571-578, 2024 May 10.
Article En | MEDLINE | ID: mdl-38726716

BACKGROUND: Controlled antegrade and retrograde subintimal tracking (CART) is rarely performed in contemporary chronic total occlusion (CTO) percutaneous coronary intervention (PCI). AIMS: We aimed to analyse the indications, procedural characteristics, and outcomes of CART at a high-volume CTO programme. METHODS: We included all patients undergoing a retrograde CTO PCI in which CART was performed at our institution between January 2019 and November 2023. The primary endpoint was technical success. RESULTS: Of 1,582 CTO PCI, the retrograde approach was performed in 603 procedures (38.1%), and CART was used in 45 cases (7.5%). The mean age was 69.1±10.3 years, 93.3% were male, and prior coronary artery bypass graft surgery was present in 68.9%. The most common target CTO vessel was the right coronary artery (48.9%). Anatomical complexity was high (Multicentre CTO Registry of Japan [J-CTO] score of 3.6±0.9). The most common collateral used for CART was a saphenous vein graft (62.2%). Advanced calcium modification was required in 15.6% of cases. CART was successful in 73.3%. Technical and procedural success was 82.2%. Coronary perforation was diagnosed in 4 subjects (8.9%), but only 1 patient (2.2%) suffered tamponade and required pericardiocentesis. No other in-hospital major adverse cardiac events were diagnosed. CONCLUSIONS: CART is a useful technique in selected, very complex CTOs tackled with the retrograde approach. Success rates were high, while complication rates were low, considering the high anatomical complexity and baseline patient risk.


Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Male , Coronary Occlusion/surgery , Coronary Occlusion/therapy , Female , Aged , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Middle Aged , Treatment Outcome , Chronic Disease , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Retrospective Studies , Aged, 80 and over
2.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Article En | MEDLINE | ID: mdl-38715080

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Aortic Valve , Coronary Vessel Anomalies , Echocardiography, Transesophageal , Mitral Valve , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Computed Tomography Angiography , Male , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging
3.
Medicine (Baltimore) ; 103(16): e37842, 2024 Apr 19.
Article En | MEDLINE | ID: mdl-38640288

RATIONALE: Guidewire fracture is one of the biggest risks of percutaneous coronary intervention, twisting wire technique is very useful for retrieving the fractured wire, but the potential risks have been inadequately reported. Herein, we present a case of retrieval of guidewire fragments using the twisting wire technique that causes coronary perfusion. PATIENT CONCERNS: A 37-year-old male patient was admitted to our hospital for elective percutaneous coronary intervention of the left circumflex coronary artery. CLINICAL FINDINGS: For chronic total occlusion of the distal left circumflex coronary artery, antegrade recanalization by wire escalation, and parallel wire techniques were attempted. However, we shockingly found that the BMW guidewire, anchored in the right coronary artery, spontaneously fractured from the proximal right coronary artery, and a lengthy fragment of the guidewire remained in the coronary. DIAGNOSES, INTERVENTIONS, AND OUTCOMES: Many attempts were made to retrieve the remnant guidewire including the twisting wire technique, which leads to the perforation of the coronary. OUTCOMES: Finally, percutaneous retrieving procedures were stopped in favor of surgical extraction via a small coronary arteriotomy. This procedure was successful. LESSONS: To the best of our knowledge, the present case is the first reported spontaneous fracture of the guidewire. Leaving such a lengthy remnant guidewire in the artery, or leaving stenting over the wire, would impose a high risk of coronary thrombosis, perforation, and embolization. Yet, the perforation of the artery that occurred in this case, which could have had life-threatening consequences, resulted from our attempts to retrieve the guidewire using the twisting wire technique.


Angioplasty, Balloon, Coronary , Percutaneous Coronary Intervention , Male , Humans , Adult , Angioplasty, Balloon, Coronary/methods , Coronary Angiography , Percutaneous Coronary Intervention/adverse effects , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Perfusion , Treatment Outcome
4.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article En | MEDLINE | ID: mdl-38598201

OBJECTIVES: Performance of a technically sound left internal thoracic artery to left anterior descending artery (LITA-LAD) anastomosis during coronary artery bypass grafting (CABG) is critically important. We used prospectively collected data from the multicentre, randomized REGROUP (Randomized Endograft Vein Perspective) trial to investigate CABG outcomes based on whether a resident or an attending surgeon performed the LITA-LAD anastomosis. METHODS: This was a post hoc subanalysis of the REGROUP trial, which randomized veterans undergoing isolated on-pump CABG to endoscopic versus open vein harvest from 2014 through 2017. The primary end point was major cardiac adverse events, defined as the composite of all-cause deaths, nonfatal myocardial infarctions or repeat revascularizations. RESULTS: Among 1,084 patients, 344 (31.8%) LITA-LAD anastomoses were performed by residents and 740 (68.2%), by attending surgeons. Residents (compared to attendings) operated on fewer patients with high tercile SYNTAX scores (22.1% vs 37.4%, P < 0.001), performed fewer multiarterial CABGs (5.2% vs 14.6%, P < 0.001) and performed more anastomoses to distal targets with diameters > 2.0 mm (19.0% vs 10.9%, P < 0.001) and non-calcified landing zones (25.1% vs 21.6%, P < 0.001). During a median observation time of 4.7 years (interquartile range 3.84-5.45), major cardiac adverse events occurred in 77 patients (22.4%) in the group treated by residents and 169 patients (22.8%) in the group treated by attendings (unadjusted HR 1.00; 95% confidence interval, 0.76-1.33; P = 0.99). Outcomes persisted on adjusted analyses. CONCLUSIONS: Based on this REGROUP trial subanalysis, under careful supervision and with appropriate patient selection, LITA-LAD anastomoses performed by the residents yielded clinical outcomes similar to those of the attendings.


Coronary Artery Bypass , Humans , Male , Female , Aged , Coronary Artery Bypass/methods , Coronary Artery Bypass/adverse effects , Middle Aged , Treatment Outcome , Coronary Artery Disease/surgery , Internship and Residency , Coronary Vessels/surgery , Mammary Arteries/transplantation , Prospective Studies , Internal Mammary-Coronary Artery Anastomosis/methods , Internal Mammary-Coronary Artery Anastomosis/adverse effects
5.
Innovations (Phila) ; 19(2): 175-183, 2024.
Article En | MEDLINE | ID: mdl-38577864

OBJECTIVE: We evaluated the effectiveness of a consistent and structured self-practice coronary anastomosis program using a homemade low-fidelity beating-heart simulator. METHODS: An intermediary trainee was subjected to an 8-week structured self-practice program. The program was divided into 2 parts of nonbeating and beating practices with a minimum number of timed anastomoses. Each part was followed by an assessment using an objective skills assessment tool score. The beating-heart simulator was built using motorized toy blocks connected wirelessly to a smartphone application. This was coded to enable rate selection. A junior consultant was compared to the subject at the end of the program. Both were tasked to perform 1 coronary anastomosis for both off-pump coronary artery bypass (OPCAB) and minimally invasive CAB (MICS) setup. The primary outcomes were anastomotic time and score compared with the junior consultant. Secondary outcomes were progression of anastomotic time and score throughout the program. RESULTS: Overall performance of the studied subject approached the performance of the junior consultant in terms of time (OPCAB, 489 vs 605 s; MICS, 712 vs 652 s) and scores (OPCAB, 21 vs 20.7; MICS, 19 vs 20.6). There were inverse correlations between anastomosis time and number of practices for both nonbeating and beating anastomoses. Overall improvement was observed in terms of assessment scoring by 26.6%. CONCLUSIONS: A structured self-practice program using an affordable and accessible simulator was able to help trainees overcome the MICS anastomosis learning curve quicker when introduced earlier. This may encourage earlier adoption of MICS among surgeons.


Anastomosis, Surgical , Clinical Competence , Minimally Invasive Surgical Procedures , Humans , Anastomosis, Surgical/education , Anastomosis, Surgical/methods , Minimally Invasive Surgical Procedures/education , Minimally Invasive Surgical Procedures/methods , Coronary Artery Bypass, Off-Pump/education , Coronary Artery Bypass, Off-Pump/methods , Simulation Training/methods , Coronary Vessels/surgery , Proof of Concept Study
6.
N Engl J Med ; 390(16): 1481-1492, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38587995

BACKGROUND: The benefit of fractional flow reserve (FFR)-guided complete revascularization in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease remains unclear. METHODS: In this multinational, registry-based, randomized trial, we assigned patients with STEMI or very-high-risk non-STEMI (NSTEMI) and multivessel disease who were undergoing primary percutaneous coronary intervention (PCI) of the culprit lesion to receive either FFR-guided complete revascularization of nonculprit lesions or no further revascularization. The primary outcome was a composite of death from any cause, myocardial infarction, or unplanned revascularization. The two key secondary outcomes were a composite of death from any cause or myocardial infarction and unplanned revascularization. RESULTS: A total of 1542 patients underwent randomization, with 764 assigned to receive FFR-guided complete revascularization and 778 assigned to receive culprit-lesion-only PCI. At a median follow-up of 4.8 years (interquartile range, 4.3 to 5.2), a primary-outcome event had occurred in 145 patients (19.0%) in the complete-revascularization group and in 159 patients (20.4%) in the culprit-lesion-only group (hazard ratio, 0.93; 95% confidence interval [CI], 0.74 to 1.17; P = 0.53). With respect to the secondary outcomes, no apparent between-group differences were observed in the composite of death from any cause or myocardial infarction (hazard ratio, 1.12; 95% CI, 0.87 to 1.44) or unplanned revascularization (hazard ratio, 0.76; 95% CI, 0.56 to 1.04). There were no apparent between-group differences in safety outcomes. CONCLUSIONS: Among patients with STEMI or very-high-risk NSTEMI and multivessel coronary artery disease, FFR-guided complete revascularization was not shown to result in a lower risk of a composite of death from any cause, myocardial infarction, or unplanned revascularization than culprit-lesion-only PCI at 4.8 years. (Funded by the Swedish Research Council and others; FULL REVASC ClinicalTrials.gov number, NCT02862119.).


Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Myocardial Revascularization , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Aged , Female , Humans , Male , Middle Aged , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Follow-Up Studies , Kaplan-Meier Estimate , Myocardial Infarction/mortality , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/methods , Registries , ST Elevation Myocardial Infarction/etiology , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/physiopathology , ST Elevation Myocardial Infarction/therapy , Myocardial Revascularization/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Reoperation , Europe , Australasia
7.
PLoS One ; 19(4): e0300098, 2024.
Article En | MEDLINE | ID: mdl-38625996

The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development.


Coronary Artery Disease , Coronary Vessels , Humans , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Coronary Vessels/anatomy & histology , X-Ray Microtomography , Imaging, Three-Dimensional , Feasibility Studies , Reproducibility of Results , Stents , Ultrasonography, Interventional , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery
8.
Medicina (Kaunas) ; 60(4)2024 Apr 04.
Article En | MEDLINE | ID: mdl-38674246

Background and Objectives: Our study aimed to reveal the effect of using 4 mm bare-metal stents (BMS), 4 mm drug-eluting stents (DES), or 3 mm DES with 4 mm diameter balloon post-dilation strategies on long-term clinical outcomes and endpoints for large-diameter coronary artery percutaneous coronary intervention (PCI). Materials and Methods: In our study, patients who had undergone PCI were retrospectively screened between January 2014 and July 2020. The study included 350 patients and was divided into three groups; Group I (n = 134) included patients with direct 4.0 mm BMS implantation, Group II (n = 109) included patients with direct 4.0 DES implantation, and Group III (n = 107) included patients with 4mm NC post-dilatation after 3 mm DES implantation. Primary endpoints were determined as target lesion revascularisation, cardiac mortality, and myocardial infarction associated with the target vessel. Our secondary endpoint was all-cause mortality. Results: No differences were observed between the groups in terms of the baseline variables. Stent length was the highest in Group II and the shortest in Group III. There were no significant differences between the groups regarding major adverse cardiovascular events (MACE). Conclusions: Our study suggests that in percutaneous coronary interventions for non-complex lesions, there is no significant difference in MACE outcomes when directly implanting a 4 mm diameter DES, a 4 mm diameter BMS, or a 3 mm diameter DES, followed by post-dilation with an appropriately sized NC balloon when the target vessel diameter is in the range of 4 to 4.4 mm.


Coronary Vessels , Drug-Eluting Stents , Percutaneous Coronary Intervention , Stents , Humans , Male , Female , Retrospective Studies , Percutaneous Coronary Intervention/methods , Aged , Middle Aged , Treatment Outcome , Stents/adverse effects , Stents/standards , Coronary Vessels/surgery , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy
13.
Pan Afr Med J ; 47: 20, 2024.
Article En | MEDLINE | ID: mdl-38524104

In this case report, we will discuss a 74-year-old female who presented with a chief complaint of abdominal pain, bloating, anorexia, and nausea for four days which preceded after catheter ablation and anhydrous ethanol infusion vein of Marshall (VOM) one month prior. She was admitted and treated as a general patient in the general ward. After hospital admission, a pericardiocentesis was guided by B-scan ultrasonography, resulting in the extraction of 20ml of pericardial effusion, followed by catheterization for drainage. The key takeaway in this report is that anhydrous ethanol infusion VOM may not always be without risks. Hence, during the procedure, it is imperative to carefully administer the appropriate volume of anhydrous ethanol into the VOM to prevent vessel damage and associated complications.


Atrial Fibrillation , Catheter Ablation , Pericarditis , Female , Humans , Aged , Atrial Fibrillation/surgery , Ethanol/adverse effects , Infusions, Intravenous , Coronary Vessels/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods
14.
J Invasive Cardiol ; 36(3)2024 Mar.
Article En | MEDLINE | ID: mdl-38441987

OBJECTIVES: Despite the introduction of improved drug eluting stents (DES), the rate of repeat revascularization procedures following percutaneous coronary interventions (PCI) in coronary chronic total occlusions (CTO) remains high. By leaving vessels uncaged and limiting length of stented segments, drug-coated balloons (DCB) represent an appealing alternative to DES for CTO-PCI. Since data supporting the use of DCBs in CTO-PCI is scarce, we compared the outcomes of patients undergoing CTO-PCI involving DCBs vs DES only. METHODS: From 2 prospective registries, outcomes of patients undergoing CTO-PCI involving DCBs and those undergoing PCI with DES only were compared. Outcomes included major adverse cardiac and cerebrovascular events (MACCE) and cardiovascular death (CV-death). RESULTS: Overall, 157 patients were studied; 112 (71%) underwent CTO-PCI involving DCBs and 45 (29%) were treated with DES only. Mean J-CTO score was 1.84 ± 0.7. Most CTO-lesions involved the right coronary artery, 88 (56%), and 26 (17%) cases were in-stent occlusions. In the DCB group, 46 (41%) lesions were treated with DCBs alone. Mean lengths of the stented segments in the DCB vs DES cohorts were 59 ± 28 mm vs 87 ± 37 mm (P less than .001), respectively. After 12 months, the MACCE rate was higher in the DES only vs DCB group (26% vs 11%, P=.03). Length of the stented segment was an independent predictor for MACCE (HR 1.15 [95% CI, 1.05-1.26] per 10-mm stent length). CONCLUSIONS: Revascularization of CTO lesions involving DCBs appears safe and potentially lowers MACCE rates compared to treatment with DES alone. Importantly, using DCBs for CTO treatment may reduce total stent length, which determines PCI outcomes.


Chlorobenzenes , Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/diagnosis , Coronary Occlusion/surgery , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Heart , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery
15.
J Cardiothorac Surg ; 19(1): 143, 2024 Mar 19.
Article En | MEDLINE | ID: mdl-38504317

BACKGROUND: Coronary artery obstruction after percutaneous aortic replacement is a complication with high short-term mortality secondary to the lack of timely treatment. There are various predictors of coronary obstruction prior to valve placement such as the distance from the ostia, the degree of calcification, the distance from the sinuses; In such a situation some measures must be taken to prevent and treat coronary obstruction. CASE PRESENTATION: An 84-year-old male, with severe aortic stenosis and high surgical risk, who was treated with TAVR. However, during the deployment of the valve he presented hemodynamic instability secondary to LMCA obstruction. The intravascular image showed obstruction of the ostium secondary to the displacement of calcium that he was successfully treated with a chimney stent technique. CONCLUSIONS: The high degree of calcification and the left ostium near the annulus are conditions for obstruction of the ostium at the time of valve release; In this context, provisional stenting prior to TAVR in patients at high risk of obstruction should be considered as a safe prevention strategy to achieve the success of the procedure.


Aortic Valve Stenosis , Calcinosis , Coronary Occlusion , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Coronary Vessels/surgery , Heart Valve Prosthesis/adverse effects , Risk Factors , Treatment Outcome , Coronary Occlusion/etiology , Calcinosis/complications , Calcinosis/surgery , Aortic Valve Stenosis/complications , Prosthesis Design
17.
Catheter Cardiovasc Interv ; 103(4): 570-579, 2024 03.
Article En | MEDLINE | ID: mdl-38470093

Large vessel perforation during coronary intervention is a rare but potentially fatal complication, often requiring implantation of a covered stent for resolution. While technology is improving, the long-term patency of covered stents is less than drug-eluting stents, and implantation of covered stents should be used sparingly. Large vessel perforations are complex and often the perforation inflow is not located at the site of extravasation seen on angiography. This can lead to geographic miss when implanting covered stents and necessitate the implantation of additional covered stents which increases the risk for short- and long-term complications. We present a case series to further investigate the anatomy and mechanism of large vessel perforations and guidance on effective covered stent implantation.


Percutaneous Coronary Intervention , Stents , Vascular System Injuries , Humans , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/adverse effects , Stents/adverse effects , Treatment Outcome , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/etiology , Vascular System Injuries/therapy
18.
J Med Case Rep ; 18(1): 158, 2024 Mar 18.
Article En | MEDLINE | ID: mdl-38494477

BACKGROUND: Stent dislodgement is a life-threatening complication that can result in coronary artery embolization, stent thrombosis, acute myocardial infarction, and even death. Severely angulated, heavily calcified, and previously stented coronary arteries are associated risk factors. With the development of different lesion preparation techniques and the drug eluting stent era, the reported incidence of stent dislodgement has decreased to < 1% in the last few years. CASE PRESENTATION: We report a case of a 64-year-old Moroccan man complicated during percutaneous intervention in the left main artery by the loss of two stents. This complication was successfully managed by passing the stent's balloon into the stent and then fully expanding it. In our case, the device's characteristics were involved and could play a role in such complications, but it is still not well understood. CONCLUSIONS: The main treatment option is stent retrieval with different available techniques. If retrieval of the stent is impossible, crushing it against the blood vessel wall could be considered.


Angioplasty, Balloon, Coronary , Percutaneous Coronary Intervention , Stents , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Drug-Eluting Stents , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Stents/adverse effects , Treatment Outcome
19.
BMC Med Imaging ; 24(1): 53, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38429683

BACKGROUND: The diameter of the ostial and proximal left main coronary artery can be greater than 5.0 mm. However, the diameters of the mostly available coronary drug-eluting stents (DESs) are ≤ 4.0 mm. Whether high-pressure dilatation can increase the diameter of stents from 4.0 to 5.0 mm and whether post-dilatation leads to longitudinal stent deformation (LSD) of 4.0-mm-diameter stents have rarely been studied. Therefore, this study aims to evaluate LSD and stent malapposition of six types of commercially available 4.0-mm-diameter stents in China in a 5.0-mm-diameter artificial blood vessel model by optical coherence tomography (OCT) in vitro. METHODS: The left main coronary artery was simulated by a truncated cone-shaped silicone tube. The internal diameters were 4.0 mm at one end of the silicone tube and 5.0 mm at the other end. Six different types of coronary stents widely used in China were selected for this study. Each stent was respectively implanted into the simulated blood vessel and dilated to a diameter of 4.2 mm according to the stent-balloon pressure compliance table. The stents were subjected to post-dilatation with a 5.0 × 15-mm noncompliant balloon. The LSD ratio of the longitudinal axis of each stent and stent malapposition were measured through OCT, and any fractures of the stents were determined. RESULTS: None of the six types of stents fractured following post-dilatation. The longitudinal axes of the BuMA and Excrossal stents were slightly shortened, while the other stents were elongated after high-pressure post-dilatation. All stents expanded to a diameter of 5.0 mm without incomplete stent apposition, except for the Nano Plus stent, which remained malapposed after high-pressure post-dilatation. CONCLUSION: All 4.0-mm-diameter stents can be expanded to a diameter of 5.0 mm by noncompliant balloon post-dilatation without stent strut fracture. Most stents were found to be well apposed after high-pressure post-dilatation. However, LSD was observed after post-balloon dilatation. Stent malapposition might be positively correlated with the percentage change in stent length.


Stents , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Dilatation , Stents/adverse effects , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Silicones
20.
Int J Cardiol ; 405: 131974, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38493833

BACKGROUND: Patients with previous coronary artery bypass surgery (CABG) who require repeat revascularization frequently undergo percutaneous coronary intervention (PCI). We sought to identify factors associated with the decision to intervene on the native vessel versus a bypass graft and investigate their outcomes in a large nationwide prospective registry. METHODS: We identified patients who underwent PCI with a history of prior CABG from the Netherlands Heart Registration between 2017 and 2021 and stratified them by isolated native vessel PCI versus PCI including at least one venous- or arterial graft. The primary endpoint of major adverse cardiac events (MACE) was a composite of all-cause death and target vessel revascularization (TVR) at one-year post PCI. The key secondary endpoint was a composite of all-cause death, myocardial infarction (MI), and TVR at 30 days. RESULTS: Out of 154,146 patients who underwent PCI, 12,822 (8.3%) had a prior CABG. Isolated native vessel PCI was most frequently performed (75.2%), while an acute coronary syndrome (ACS) presentation was most strongly associated with graft interventions. The primary outcome of MACE at one-year post PCI occurred more frequently in interventions including grafts compared with native vessels alone (19.7% vs. 14.3%; adjOR 1.267; 95% CI 1.101-1.457); p < 0.001) driven by TVR. There was however no difference in mortality or the key secondary endpoint between the two groups. CONCLUSION: In this nationwide prospective registry, ACS presentation was strongly associated with bypass graft PCI. At one year after PCI, interventions including bypass grafts had a higher composite of MACE compared with isolated native vessel interventions.


Coronary Artery Bypass , Coronary Artery Disease , Percutaneous Coronary Intervention , Registries , Humans , Male , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/trends , Percutaneous Coronary Intervention/adverse effects , Female , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/trends , Netherlands/epidemiology , Aged , Middle Aged , Prospective Studies , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Treatment Outcome , Follow-Up Studies
...